LLT600/13 - A Low Loss Transfer tube (LLT) for horizontal feed cryostats: 1.3m Dewar Leg, 1.2m Flexible Section.
NW/KF 10mm Centering Ring with Viton 'O-ring. Centering Rings are used to connect two flanges of different internal sizes. This creates a vacuum seal with the use of a clamp. (10mm size)
ISO 100 K-F Adaptor flange for use with a Triton dilution refridgerator.
LLT600/13 - A Low Loss Transfer tube (LLT) for horizontal feed cryostats: 1.3m Dewar Leg, 1.5m Flexible Section
Corrugated Flexible Pumping Line for transferring liquids and gases where high and low temperatures, or corrosion are important factors. (NW16 Fittings - 3metre)
Corrugated Flexible Pumping Line for transferring liquids and gases where high and low temperatures, or corrosion are important factors. (NW40 Fittings - 2metres)
Corrugated Flexible Pumping Line for transferring liquids and gases where high and low temperatures, or corrosion are important factors. (NW25 Fittings - 3metre)
Aluminium pin stubs, 32mm in diameter. SEM Specimen Stubs for LEO/CAMBRIDGE, FEI/PHILIPS, CAMSCAN, TESCAN, ZEISS instruments. Pin length 8mm. Pack of 50.
Pfeiffer Turbo-Cube OVC pump with gauge and cable. 110V.
This large capacity, compact turbo pumping station offers the additional ability of evacuating large volumes such as those of magnet dewars.
LLT600/13 - A Low Loss Transfer tube (LLT) for horizontal feed cryostats: Transfer Tube: 1.3m Dewar Leg, 1.8m Flexible Section
Rhodium-Iron Resistance Sensor (range 1.4 - 800K) fully calibrated 1.4 - 300K. The excitation current is typically around 1mA, which gives a resulting temperature change due to self heating of less than 1mK.
A range rust and corrosion resistant Dewars with cushioned bases in a series of different sizes that come with wide or narrow necks, without a handle or lid. Ideal for cold traps. (2L Size)
Ruthenium Oxide Temperature Sensor Generic Calibration consisting of a thick film Ru2O chip sensor mounted in a gold-plated copper holder. This sensor is generically calibrated. Temperature range 50mK - 4.2K. This is a thick-film resistor best used in applications involving magnetic fields.
A 4.5L rust and corrosion resistant Dewar flask with a cushioned base and a fold down handle and insulated lid. (4.5 Litres)
Sapphire Outer Window (Optistat CF/DN new style). Sapphire is an alternative window for visible and near IR applications.
Cernox Resistance Sensor Canister Uncalibrated for use in magnetic fields up to and in excess of 20T and is the best choice for cryogenic work. The cannister model is more robust and convenient for insertion holes. It has four colour-coded leads. This model is not calibrated.
NW KF 16mm Electrically Isolating Carrier and O ring with a temperature range of -10 to 100⁰C. (16mm)
O Ring ESR Vacuum Quartz Upper (old style). Material: Nitrile. Before using, the surface of the O-ring must be free of releasing grease or talcum, smooth and crack-free and scratch-free.
Alcatel Adixen Pfeiffer ACP28 Pump. The ACP28 Pump is an oil free pump used to circulate helium3 mixture in our range of Triton and Kelvinox dilution refrigerators.
LLT700/10 - A Low Loss Transfer Tube for vertical feed cryostats: 1.0m Dewar Leg, 1.3m Flexible Section.
Pump nXDS10iR Scroll (OI System ready) • Oxford Instruments system ready Vacuum pump • Oil free • Pumping speed 10 m3/hr.
With exceptional pumping capability, ultimate vacuum performance and state-of-the-art design features, the nXDS dry scroll pump is the best performing pump in its class.
Special TTN2F Helium transfer tube manufactured to customer specified dimensions - custom lengths available.
Band Spring for Optistat Thermal Link which achieves a thermal contact between the Optistat and its sample rod.
Cernox Resistance Hermetic Uncalibrated Standard Sensor for use in magnetic fields. Temperature Range 1.4-420K, For use in fields up to 20T. This is the hermetic model which is advisable to use in situations that require a reduced size or a fast thermal response. It has high sensitivity at low temperatures and good sensitivity over a broad range.
Blanking Flange in Stainless Steel DN/KF 16mm to cover unused openings and prevent contamination of clean spaces.
NW/KF 40mm Aluminium Clamp used to clamp two flanges to a Centering ring and an O Ring creating a vacuum seal.
General Purpose Transfer Tube TTN2F Standard Flexible, 0.5M Dewar Leg. Compatible with dewar top fitting SV10. 0.5m Dewar leg, Typical flow rates of 1l/min at 0.1bar.
Self-pressurising Liquid Nitrogen Dewar 120 litres. Self pressurising liquid nitrogen vessels is suitable for a host of applications within the industrial, medical, research and cryo-biological fields.
Flexible Film Heater 25W, 25 ohm. An economical film heater with working temperatures up to 200ºC.
The dimensions of the Film Heater 25W, 25 ohm (59-PFZ0004) are 25mmX50mmX0.5mm.
Liquid Helium Dewars 120 litres - NW50 - Low temperature transport and storage container for liquid helium.
O' Ring New Style ESR Sample Tube. Before using, the surface of the O-ring must be free of releasing grease or talcum, smooth and crack-free and scratch-free.
Needle valve heater and sensor assembly for the Spectromag SM4000 superconducting magnet.